Error: Philips Speedpro Max E4

Software Tip: If the nozzle is jammed, the E4 might have "latched" into memory. Try plugging the vacuum into the charger for 10 seconds after clearing the brush jam. This sometimes resets the error flag.

If the error only appears when the mopping unit is attached, your mopping unit is faulty. You can continue using the vacuum as a dry stick vac by leaving the water tank off. philips speedpro max e4 error

The Philips SpeedPro Max is a high-performance cordless stick vacuum celebrated for its powerful suction, PowerCyclone 10 technology, and long runtime. However, like any sophisticated piece of electro-mechanical hardware, it is susceptible to errors. Among the most frustrating issues reported by users is the sudden appearance of the on the handle display. Software Tip: If the nozzle is jammed, the

8 thoughts on “GoldenGate Microservices architecture hands-on

  1. philips speedpro max e4 error

    GG Microservices is the epitome of over-engineering. A group of tech-bros got together and asked how can we take a simple one installation tool and make it more complex but also make it useless at the same time. And 23ai is now the height of that stupidity. They’re like the guys on 30 Rock that was tasked with enhancing a microwave and ended up turning it into the Pontiac Aztek.
    Service Manger has links back to itself on the same main page. Some links that just open up the same page, but in a new tab. They took simple one line commands like “add credentialstore” that you could put into an obey file and turned them into https curl nightmares that they claim is “simplified”.
    I can build out a 19c classic deployment that includes the adapter with a kafka handler sending data to Azure EventHub in the same time it takes someone just trying to wade through the mess that is the oggca response file.
    It’s a shame too, because the classic architecture is some really good replication software.

  2. philips speedpro max e4 error
    Raymond Munene says:

    Update:

    Executed the PL/SQL without the container=’ALL’ option and it completed. Not sure what the effects of omitting that option are but I guess I will find out once I set up extract & replikat

    • philips speedpro max e4 error

      Hi Raymond,

      Default option is container=’CURRENT’ so yes you might end up with an issue…
      From the official documentation: “To specify ALL, the procedure must be invoked in the root by a common user.”.
      Have you executed this from the root container ?

  3. philips speedpro max e4 error
    Raymond Munene says:

    Hi Yannick,

    Facing this issue when granting dbms_goldengate_auth.grant_admin_privilege but it keeps failing. Logged the issue with support but no solution given yet.

    SQL> EXEC dbms_goldengate_auth.grant_admin_privilege(grantee => ‘C##GGADMIN’, privilege_type => ‘CAPTURE’, container => ‘ALL’);

    *
    ERROR at line 1:
    ORA-44001: invalid schema
    ORA-06512: at “SYS.DBMS_XSTREAM_AUTH_IVK”, line 3652
    ORA-06512: at “SYS.DBMS_ASSERT”, line 410
    ORA-06512: at “SYS.DBMS_XSTREAM_ADM_INTERNAL”, line 50
    ORA-06512: at “SYS.DBMS_XSTREAM_ADM_INTERNAL”, line 3137
    ORA-06512: at “SYS.DBMS_XSTREAM_AUTH_IVK”, line 3632
    ORA-06512: at line 1
    ORA-06512: at “SYS.DBMS_XSTREAM_AUTH_IVK”, line 3812
    ORA-06512: at “SYS.DBMS_GOLDENGATE_AUTH”, line 63
    ORA-06512: at line 1