Fanuc 414 Servo Alarm Z Axis Detect Error Repack Repack Page
: Excessive resistance in the Z-axis (e.g., tight gibs, failed thrust bearings, or a binding brake) forcing the motor to draw excess current.
Common sub-codes associated with a 414 alarm include: fanuc 414 servo alarm z axis detect error repack
80% of “detect error” alarms are cable/connector problems, not internal motor failure. : Excessive resistance in the Z-axis (e
| Symptom | Likely Cause | Solution | | :--- | :--- | :--- | | Alarm happens | Loose cable connector or internal brake drag | Tighten connector; measure brake voltage (90VDC typical) | | Alarm happens immediately at power-up | Shorted cable or dead encoder | Replace cable first. If persists, replace pulse coder. | | Alarm happens when releasing the brake | Brake coil shorted | Measure brake coil resistance. Should be 50-200 ohms. Open or short = replace motor. | | Alarm happens when moving the Z-axis down | Cable flex break | Wiggle the Z cable while watching the diagnostic screen (FANUC Diag 200-204). | If persists, replace pulse coder